Solutions

Water Tanks & Swimming Pools

Terraco has a wide range of waterproofing products that are ideal for structures that store standing water and in few cases, potable water. Below are the products ideal for waterproofing swimming pools and water tanks.

Products for Water Tanks & Swimming Pools

Installation guide: How to waterproof a bathroom before tiling

A wet-area waterproofing procedure covering falls, fillets, corner tape, two-coat membrane application and flood testing before tiles go down.

Typical duration
4D
Tools
Angle grinder or scabbler for laitance removal, Block brush and 4 mm notched trowel, Spirit level or laser for fall check, Bucket, paddle mixer
Materials
Cementitious or flexible waterproof membrane (e.g. Terraseal), Reinforcing tape for corners and junctions, Polymer bonding primer, Non-shrink repair mortar for fillets
  1. 1

    Strip and inspect

    Remove old finishes back to sound screed or concrete. Check for cracks, honeycombing and loose sand-cement. Confirm all plumbing rough-in is complete and pressure tested — no penetration may be cut after waterproofing.

  2. 2

    Correct the falls

    Verify a minimum 1:100 fall towards the floor waste, and 1:80 inside a shower area. Re-screed flat or ponding areas; a membrane cannot compensate for standing water.

  3. 3

    Form fillets and repair

    Cut out cracks, fill with repair mortar, and form a 25 mm cove fillet at every wall-floor junction so the membrane is never asked to turn a sharp 90° angle.

  4. 4

    Prime the substrate

    Dampen or prime per the membrane data sheet. Cementitious membranes usually need a saturated surface-dry substrate; acrylic ones need a fully dry, primed one.

  5. 5

    Band the movement points

    Bed reinforcing tape into a wet first pass of membrane at all internal corners, wall-floor junctions, drain flanges and pipe penetrations. This detail is where nearly all wet-area leaks begin.

  6. 6

    Apply two coats

    Brush the first coat over the full floor and up walls to 1.8 m in showers and 150 mm elsewhere. Once touch-dry, apply the second coat at right angles to the first to eliminate pinholes. Respect the total wet film thickness in the data sheet.

  7. 7

    Flood test

    After full cure, plug the drain, flood the floor to 25 mm and hold for 24 hours. Check the ceiling and walls below. Only a passed flood test releases the area for tiling.

  8. 8

    Tile with a compatible adhesive

    Use a polymer-modified C2 adhesive over the membrane. Never mechanically fix through the membrane; if a fixing is unavoidable, seal it with membrane and tape.

Read the full guide
Request technical support